Opis
MeteoWind 2
Anemometer with a wind vane. Exceeds WMO and MEASNET Class 1 accuracy standards for meteorology & wind resource assessment. Very low 4mA combined power consumption and integrated triple layer lightning & surge protection for reliable
operation. Protected oversize bearings with high dirt and weather resistance proven to provide long-term measurement stability & reliability in dirty & dusty environments.
Serviceable bearing & cups with high dirt resistance
• Serviceability of rotor bearing, anemometer cups and wind vane
• Special double-arm reinforced cup design with over-size bearings for robustness.
• Highest level of 3 stage lightning, EMC, Surge & ESD protection
• Industry standard RS-485 output
• Simple & robust MODBUS RTU and ASCII communication protocol is user selectable
• Long-term tested dirt resistance in highly dusty environments with salt-spray
• All models feature a weather proof locking bayonet connector.
Dual arm reinforced cup design for all weather reliability
• WMO & MEASNET conforming wind speed and direction.
• 10Hz sampling rate to accurately capture wind gusts.
• Fast response and minimal over-speeding for accurate
wind gust measurement.
• Robust two arm reinforced rotor cup design
• Special flat elliptical cups offer superb snow shedding
with very good hail resistance
• All-metal replaceable wind direction vane.
• Strong all-metal anodized-aluminum body
Measurement standards of anemometer & wind vane | ||||
Range | Resolution | Accuracy | Sampling rate | |
Wind speed | 0-80 m/s gust | 0.01m/s | < 1% of measured value (0.3 – 50 m/s) or < ±0.2 m/s ±0.05m/s (4-16m/s) with MEASNET CALIBRATION | 10Hz @ 3 pulses per revolution |
Wind direction | 0-360° | 1° | 2° (no dead-spot) | 10Hz |
Linearity | R2 > 0.99995 MEASNET/IEC 61400-12-1:2005 | |||
Tilt angle sensitivity | Cosine response, see graph. (Horizontal wind speed measurement) | |||
Starting wind speed | <0.3m/s | |||
Default linearity constants (Calibration equation coefficients) | Defaults: Slope = 0.43 m/s | Offset = 0.33 m/s (m/s = 0.43*freq(Hz) + 0.33)For MEASNET accuracy without calibration: Slope = 0.4341 m/s | Offset = 0.3054 m/s | |||
Distance constant (Delay distance) | <3m (est.) (per ASTM D 5096-96) | |||
Electrical specifications of anemometer & wind vane | ||||
Output signal & communication | RS-485 with Modbus RTU & ASCII | |||
Supply Voltage | 5…24VDC with inrush protection & reverse polarity protection | |||
Power consumption | 2.6mA @12V (combined wind speed & direction at 10Hz sampling including RS-485 coms) | |||
Lightning & surge protection | per IEC EN 61000-4-5 on both data & power lines, Surge, EFT/Burst, ESD 15kV | |||
Environmental rating of anemometer & wind vane | ||||
Operating temperature | -40°C to +80°C | |||
Operating humidity range | 0% to 100% RH | |||
Survival wind speed | >90m/s (324kph, 200mph) | |||
Connection | Bayonet connector with silicone o-ring | |||
IP – Protection rating | IP55W (DIN 40050) | |||
General anemometer & wind vane specifications | ||||
Heater (optional) | 20W (1.1A) @ 24VDC (5W @ 12VDC), User selectable manual or automatic heater control | |||
Weight (mass) | Anemometer = aprox. 300g (without stainless steel mount) | |||
Dimensions | Anemometer rotor diameter = Ø164mm, Wind vane radius =136mm, Total height = 320mm | |||
Patented / Registered | OHIM 002153882-0001, 002153882-0002, 002153882-0003 | |||
Mounting | two M4 screws with supplied holder as pictured below |